11 Regelbau Bunkers That Reveal the Atlantic Wall’s Hidden Design

Concrete architecture · German military engineering · WWII field guide

11 Regelbau Bunkers That Reveal the Atlantic Wall’s Hidden Design

From a ten-man infantry shelter to the Luftwaffe’s “Bertha” radar-control bunker, these eleven standard designs expose the different jobs hidden inside Germany’s wartime concrete fortifications.

11 JSON-listed bunker types88 unique catalogue-tagged photographs8 images per typeModel-by-model research

Eleven designs, eleven different military jobs

The word Regelbau is often used as though it meant one standard kind of German bunker. In reality, it describes a system of planned designs. Each type was developed for a specific task, and the details matter: the shelter for a ten-man infantry group was not the same building as a machine-gun turret, a coastal artillery command post or a radar-control centre.

This guide selects eleven type labels that actually occur in the supplied Pinterest image JSON: Regelbau 621, 622, 634, 636, 639, 666, 668, 671, L411A, L487 and V174. Each section has eight distinct photographs drawn from entries whose type field matches that exact designation. Some types also have an additional independently hosted reference photograph.

Captions retain the source file’s classification label; a label is useful catalogue evidence, but it is not a substitute for a measured survey or archival identification of every photographed building. Technical figures are presented as standard-plan or catalogue values where a reliable record supplies them. They should not be read as universal measurements for every surviving bunker: site adaptations, plan revisions, incomplete construction and later alterations all affect what can be measured today.

How to read the model names: numbers without a letter prefix in this selection are Army designs; the L models belong to the Luftwaffe family; and V174 is listed in a separate V-series radar/communications grouping in specialist model references. Service labels and exact equipment must still be checked against the individual model and its installation.

At a glance: the selected Regelbau types

ModelService / programmeDocumented main functionDesign release in catalogue
621HeerTen-man group shelterQ4 1942
622HeerTwo-group / twenty-man shelterQ4 1942
634HeerSix-embrasure MG turret bunkerQ4 1942
636HeerCoastal-battery command / fire-control postQ4 1942
639HeerLarge medical dressing stationQ4 1942
666Aachen–Saar programmeInfantry observation post with small cupolaQ1 1943
668HeerSix-man crew shelterQ1 1943
671Heer120° frontal casemate for 10.5 cm gunQ2 1943
L411ALuftwaffe60 cm AA searchlight garage / machinery shelterQ1 1942
L487Luftwaffe“Bertha” night-fighter radar evaluationQ1 1943
V174V-series radar / communicationsRadar equipment stand / bunkerQ3 1943

Dates and functional descriptions are catalogue design information, not a claim that every example was built on the release date or completed exactly to the standard drawing.

01 / HEER · PERSONNEL SHELTER

Regelbau 621: The Ten-Man Group Shelter

Regelbau 621 is one of the most recognizable Army personnel-shelter designs in the coastal-defence catalogue. Its model description is direct: a group shelter for ten men. The design was released in the final quarter of 1942, when German engineers were standardizing the accommodation and protection provided to infantry units across the western defences. Its job was not to fight as a gun casemate. It was to give a small group a protected place to rest, take cover and maintain readiness close to the position it supported.

The nominal plan data recorded by BunkerArchive gives a footprint of about 9.8 by 9.7 metres, a height of 5.1 metres and a concrete volume of approximately 410 cubic metres. Those are catalogue values for the standard design, not measurements guaranteed at every surviving site. The Bretagne regional heritage inventory describes a documented example at Pointe de Bloscon, Roscoff, built in 1943 under Organisation Todt: a reinforced-concrete shelter with a troop room of about 20.9 square metres for ten soldiers, two entrances and a gas lock. The inventory describes the roof slab and perimeter walls as approximately two metres thick at that example.

Why the 621 has more than a simple entrance

The two-entry arrangement mattered. A protected entrance route could be closed off from the living compartment through a gas lock, while an alternative exit improved access and escape. Some examples were associated with an external ringstand or close-defence position, but that feature should not be assumed on every 621: the documented Roscoff inventory describes an external circular position, while the standard plan and later modifications could vary. The model is also discussed as a development of the earlier 501 group shelter, adapted to a ten-man infantry group; exact local arrangements should be checked against the site drawing.

Plan referenceHeer · 10-man group shelter · design release Q4 1942Catalogue dimensionsApprox. 9.8 × 9.7 m footprint; 5.1 m high; 410 m³ concreteDocumented examplePointe de Bloscon, Roscoff, France · built 1943

Sources: Bretagne regional heritage inventory, Roscoff 621; Lexikon der Wehrmacht, Regelbau 621; BunkerArchive type record.

02 / HEER · DOUBLE GROUP SHELTER

Regelbau 622: A Shelter Built for Two Infantry Groups

Regelbau 622 expanded the group-shelter idea into a larger accommodation block. The catalogue designation identifies it as a twin group shelter for twenty men: effectively two infantry groups under one reinforced-concrete roof. That makes it different from the ten-man 621 not merely in scale, but in the way it concentrated personnel in one protected location. A larger shelter could support a more substantial defended locality, provided it remained connected to the trenches, fighting positions and routes used by the unit.

Plan data lists the design in the permanent-construction category and gives approximate outer dimensions of 11.5 metres wide, 12.6 metres long and 5.1 metres high. Published concrete figures vary around 629–650 cubic metres, so they are best treated as a range in the available catalogue record rather than a precise amount for every build. The design belongs to the Army’s standardized programme and is recorded from the final months of 1942.

Close defence was a separate problem

A large shelter was not automatically a combat bunker. Its occupants still needed protection against an infantry attack at the entrance or from the blind side of the structure. The Normandy heritage inventory for the site known as Les Landes at Fermanville identifies a Regelbau 622 shelter intended for two combat groups and protected in close defence by two Tobruk positions. The inventory notes that vegetation prevented the survey team from entering or inspecting the structure, so it records the type and intended arrangement without claiming a full interior survey. This is an important example of how a standard personnel shelter could sit inside a wider defensive composition.

The Fermanville record also locates the 622 within a site classified as a radio-wave station. That site context should not be misread as proof that the 622 itself was a radar bunker: the inventory describes the building as an “abri” for two combat groups, with separate Tobruk positions for close protection.

Primary functionProtected accommodation for two infantry groups / about twenty menCatalogue planApprox. 11.5 × 12.6 m footprint; about 5.1 m highDocumented exampleLes Landes, Fermanville, Normandy · two Tobruk close-defence positions recorded

Sources: Université de Caen Normandie / DRAC, Fermanville inventory; BunkerArchive type record.

03 / HEER · ARMOURED TURRET COMBAT BUNKER

Regelbau 634: Six Embrasures, Two Machine Guns

Regelbau 634 was a combat bunker built around a small armoured turret with six embrasures. The catalogue describes the turret as the central feature of the design, and records two MG 34 machine guns as its armament. Rather than relying on a single narrow firing slit, the turret’s multiple embrasures allowed the crew to observe and engage targets across a much wider arc, while the armoured cupola shielded the machine-gun team from small-arms fire and fragments.

The standard model record gives a building footprint of roughly 11.4 metres by 10.7 metres, a height of about 5.1 metres and an estimated 630 cubic metres of concrete. The design release is listed in the fourth quarter of 1942. These values describe the standard design; armoured components, the turret opening and the actual site arrangement are the most useful identification clues when comparing a surviving structure with a plan.

What made the turret important?

The turret was both an observation and a fighting component. Six embrasures distributed around it reduced the blind sectors that would have limited a fixed frontal aperture. It was not equivalent to a large artillery turret: the weapons were machine guns for local defence. A local history account in the Sydthy yearbook identifies a Regelbau 634 at Agger and describes the six-embrasure cupola and its machine-gun role; Lexikon der Wehrmacht likewise associates the model with two machine guns in the armoured turret. The exact state of fittings in a surviving example will depend on post-war removal, corrosion and restoration.

Primary functionArmoured-turret machine-gun combat bunkerArmament listedTwo MG 34 machine guns in a six-embrasure turretCatalogue planApprox. 11.4 × 10.7 m; 5.1 m high; 630 m³ concrete

Sources: Sydthy Årbog 2016, Agger defences; Lexikon der Wehrmacht, Regelbau 634; BunkerArchive type record.

04 / HEER · COASTAL ARTILLERY COMMAND

Regelbau 636: The Command Post Behind the Guns

Regelbau 636 was designed as a command post for an Army coastal battery. Its task was to connect the observation and command functions of a battery, rather than to house the gun itself. A coastal artillery position depended on more than the weapon and its crew: observers had to report targets, range and bearing information had to be assessed, and orders had to reach the gun detachments. A dedicated protected command building provided the fixed point where that work could be coordinated.

The plan record gives the 636 a substantial scale: approximately 18.4 metres long, 15.5 metres wide and 6.2 metres high, with about 960 cubic metres of concrete. It is listed as an Army design released in the fourth quarter of 1942. The building belongs to the “fire-control posts for coastal batteries” functional group. This makes its architectural purpose different from a troop shelter, ammunition store or gun casemate, even though such structures could stand within the same battery complex.

Command is not the same as observation

A command post could receive information from a separate observation post or range-finding station. It is therefore a mistake to assume that every 636 contained the battery’s primary seaward observation instrument. The exact equipment and room-by-room arrangement require the relevant plan version or a site survey. At the scale recorded for the standard design, the building could provide protected working rooms and communications facilities for the battery command staff, but the catalogue dimensions alone do not establish the exact equipment installed at a particular location.

For researchers, the 636 is a useful reminder to read a battery as a distributed system. A large command bunker might be relatively inconspicuous compared with a massive gun casemate, yet its role was central to the coordination of fire.

Primary functionArmy coastal-battery command and fire-control postStandard plan dataApprox. 18.4 × 15.5 m; 6.2 m high; 960 m³ concreteDesign releaseQ4 1942, permanent construction category in the catalogue

Sources: BunkerArchive, Regelbau 636; Atlantvolden.dk, Vigsoe site and 636 plan reference.

05 / HEER · MEDICAL FACILITY

Regelbau 639: A Large Dressing Station Under Concrete

Regelbau 639 was a large medical shelter, designated Großer Sanitätsunterstand in the model catalogue. Its role was to provide a protected medical facility within a defended area. Casualties from a coastal battery or infantry strongpoint needed somewhere to be assessed, treated and prepared for evacuation. A dressing station was not necessarily a full hospital, and its function should not be confused with a long-term treatment facility farther behind the front.

The model record gives dimensions of approximately 21 metres by 14 metres and a height of 5.1 metres. Its estimated concrete volume is around 1,360 cubic metres, making it one of the larger medical-related designs in the selected group. It is classified as an Army permanent bunker and the design is recorded in the fourth quarter of 1942. The dimensions and concrete figure are standard catalogue data, not proof that every installation was completed exactly to the original plan.

What can and cannot be said about the interior

The available model references securely establish the building’s medical dressing-station function and its large footprint. They do not provide a sufficiently consistent, independently verified patient-capacity figure for every version, so no number of beds or wounded men is stated here. The exact division between treatment areas, stores, staff rooms and circulation spaces must be checked against a surviving plan or a documented example. This restraint matters: a large concrete volume alone does not reveal how a wartime medical unit was organized.

Unlike a machine-gun bunker, a 639 was not designed to engage an assault. Its military value lay in the ability to keep casualties under cover, support medical personnel and maintain the fighting strength of the surrounding garrison. It is one of the clearest reminders that permanent fortifications contained support functions as well as weapons.

German designationGroßer Sanitätsunterstand — large medical dressing stationCatalogue plan dataApprox. 21 × 14 m; 5.1 m high; 1,360 m³ concreteInformation limitNo patient or bed capacity is stated because a reliable figure was not verified

Sources: BunkerArchive, Regelbau 639; Krigen i Danmark, wartime hospital facilities.

06 / INFANTRY · OBSERVATION POST

Regelbau 666: The Small Armoured Observation Cupola

Regelbau 666 is described as an infantry observation post with a small armoured cupola. Its defining feature is the protected observation point, not a heavy gun or a large turret. From a compact protected position, personnel could observe the surrounding ground and report movement to the local command. The model record also associates the design with an observation function and gives a standard concrete volume of about 420 cubic metres, with approximate outer dimensions of 11.6 metres long, 7.4 metres wide and 6.6 metres high.

One classification point deserves care: BunkerArchive places the 666 under the “Regelbauten Aachen-Saar” programme rather than the same coastal Regelbau series in which the 621 and 622 appear. Its presence in the uploaded image collection makes it a valid type for this article, but it should not automatically be presented as a standard Atlantic Wall design. The model illustrates the broader German practice of using a compact protected observation structure where the tactical situation demanded it.

Observation and combat were different jobs

The small armoured cupola provided a protected position for looking out, while the bunker’s internal rooms supported the observers and their work. Depending on the plan version, observation information could be plotted or passed to nearby fighting positions. It is not the same as the Regelbau 634: the 634’s six-embrasure turret was a machine-gun fighting system, whereas the 666 is catalogued primarily as an observation post. That distinction is essential when identifying structures from exterior photographs.

There is a published specification discrepancy worth preserving. BunkerArchive lists approximately 420 cubic metres of concrete, while another model description in Lexikon der Wehrmacht gives a lower figure. The values may reflect different plan variants or accounting conventions; without the exact drawing version, it is safer to report the discrepancy than to present one as universal.

Primary functionInfantry observation post with small armoured cupolaCatalogue plan dataAbout 11.6 × 7.4 m; 6.6 m high; 420 m³ listed by BunkerArchiveClassification noteCatalogue places this model in the Aachen–Saar programme; not every 666 should be labelled an Atlantic Wall installation

Sources: BunkerArchive, Regelbau 666; Regelbau.dk model record and gallery.

07 / HEER · SIX-MAN CREW SHELTER

Regelbau 668: Six Men, a Stove and a Close-Defence Role

Regelbau 668 was a small six-man crew shelter. The official Bunkermuseum Hanstholm description is unusually valuable because it connects the standard type to actual structures in the 38 cm battery landscape. The museum records two 668 crew bunkers, building numbers 1234 and 1249, which were intended to house part of the crew responsible for protecting the battery against enemy infantry attacks. The museum says the bunker contained bunks for six men, a tiled stove and a hand-operated ventilation system.

The published standard dimensions are approximately 7.65 by 7.65 metres and 4.4 metres high, with about 210 cubic metres of concrete. The model is listed as an Army permanent construction, with a design release in the first quarter of 1943. The museum’s layout description identifies an entrance, gas lock, crew compartment, emergency exit and a machine-gun/observation position. It therefore provides a strong example of how crew accommodation and local protection could be combined in one compact installation.

A real example at Hanstholm

The Hanstholm record says the two bunkers were excavated in October 2006, making them part of a museum-managed landscape that can be studied alongside the much larger gun battery. The museum text gives one casting date in a way that appears to contain a typographical error (“1994”) for building 1234; it records 5 October 1944 for building 1249. The error should not be silently corrected without checking the museum’s underlying documentation, so this article avoids using the disputed date.

The 668 is easy to underestimate because it is much smaller than a gun casemate or radar control bunker. But a battery needed men to man its perimeter and defend its blind approaches. A shelter that kept those men protected and ready was part of the operational life of the fortress.

Primary functionSix-man personnel / crew shelter with a close-defence roleCatalogue plan dataApprox. 7.65 × 7.65 m; 4.4 m high; 210 m³ concreteDocumented examplesTwo crew bunkers in the Hanstholm 38 cm battery museum area

Sources: Bunkermuseum Hanstholm, museum area (Regelbau 668); BunkerArchive type record.

08 / HEER · 10.5 CM GUN CASEMATE

Regelbau 671: A 120-Degree Casemate for a Coastal Gun

Regelbau 671 was a frontal casemate for a centrally pivoting gun, designed around a stated firing sector of 120 degrees in the standard plan. The model catalogue associates it with a 10.5 cm Kanone 332 (f), a French-origin weapon used by German coastal artillery. The casemate protected the gun crew and the gun’s working position while limiting its traverse to the sector covered by the embrasure. That is the key trade-off compared with an open gun platform: the weapon gained protection, but its field of fire became more restricted.

The catalogue dimensions are about 10 metres wide, 9.6 metres long and 5.1 metres high, with approximately 310 cubic metres of concrete. The type was released in the second quarter of 1943. Real examples were not always identical. At Oddane Fort in Norway, the state management plan records a casemate built to Regelbau 671 but with side rooms somewhat wider than the German standard drawing; it was partly blasted into rock and lined with reinforced concrete. The record further notes later changes to the gun and the external foundation.

Regelbau 671 in Normandy and Norway

The University of Caen Normandie and DRAC inventory records the construction of six Regelbau 671 casemates at La Pernelle in mid-April 1944 for 10.5 cm K.331 guns. They belonged to the H.K.B. Hessen battery and were supported by a separate fire-control post and scattered ammunition stores. This confirms the 671’s role as one element in a battery, rather than a self-contained installation that could operate without observation and supply.

At the preserved Oddane example, the side rooms and embrasure were adapted to the site. Such variations are not errors in the model identification; they reflect the practical work of fitting a standard plan to local rock, terrain and later service needs. A 671 should therefore be identified by its basic casemate form and checked against its actual construction details before its exact variant is stated.

Primary functionFrontal casemate for a centrally pivoting 10.5 cm coastal gunStandard firing arc120 degrees in the catalogue description; local adaptations existedDocumented examplesLa Pernelle, Normandy (six built in 1944); Oddane Fort, Norway (modified example)

Sources: Université de Caen Normandie / DRAC, La Pernelle battery inventory; Forsvarsbygg, Oddane Fort management plan; BunkerArchive type record.

09 / LUFTWAFFE · SEARCHLIGHT MACHINERY BUNKER

Regelbau L411A: The Hidden Garage Behind a 60 cm Searchlight

Regelbau L411A belonged to the Luftwaffe and was designed for a 60-centimetre anti-aircraft searchlight. Its German description, Unterstand für Flakscheinwerfer 60 cm, makes clear that it was not an artillery casemate. The building served as a protected shelter and garage for the searchlight installation and its supporting machinery. At night, searchlights could illuminate aircraft so anti-aircraft guns could engage them, but the light itself depended on a complex support system: generator, fuel, cables, equipment, maintenance and trained crews.

The model catalogue lists a plan footprint of about 13 metres long by 10.6 metres wide, a height of 5.1 metres and roughly 680 cubic metres of concrete. It is recorded as a permanent Luftwaffe design released in the first quarter of 1942. The technical room descriptions available from the Regelbau.dk model record include a gas lock, a crew/readiness room, storage, a garage space, an engine room and fuel/equipment areas. Because the available page is a specialist model catalogue rather than a surviving site inventory, these room labels should be checked against the specific drawing version when documenting an individual example.

Why the generator matters

A large searchlight required a source of electrical power and a protected operating routine. The bunker’s garage and engine spaces show how the German air-defence system had to protect equipment as well as people. The L411A was an enabling structure: it helped keep the searchlight available and maintained, while the actual beam and the nearby gun positions formed part of a larger anti-aircraft battery. It is therefore best understood as a technical support bunker for night air defence, not as a weapon position in its own right.

ServiceLuftwaffePrimary functionProtected garage / machinery shelter for a 60 cm Flak searchlightCatalogue plan dataApprox. 13 × 10.6 m; 5.1 m high; 680 m³ concrete

Sources: Regelbau.dk, L411A model description and gallery; BunkerArchive type record.

10 / LUFTWAFFE · NIGHT-FIGHTER CONTROL

Regelbau L487 “Bertha”: A Concrete Radar Operations Room

Regelbau L487, nicknamed “Bertha”, was a Luftwaffe bunker for radar evaluation and night-fighter control. It belonged to the communications and command layer of the air-defence system rather than to the coastal gun network. Radar stations reported aircraft movements; those observations had to be gathered, compared and plotted before fighter controllers could direct night fighters towards targets. The L487 protected the people and equipment that turned radar information into an operational air picture.

The BunkerArchive model entry describes it as the night-fighter-control bunker “Bertha” and lists a very substantial standard structure: approximately 22.9 metres wide, 22.1 metres long and 8.6 metres high, with around 2,550 cubic metres of concrete. The design date is recorded as the first quarter of 1943. The building’s large volume reflects the different demands of an operations centre: communications equipment, evaluation spaces and personnel were concentrated in one protected facility.

How the Bertha system worked

Visit Wadden’s historical account describes the way radar tracks from a wider area were gathered at standard evaluation centres such as L487. Positions of friendly and enemy aircraft were projected onto a large glass situation table known as a Seeburgtisch, with geographical references and coastline information. Controllers could then direct German night fighters towards selected targets and relay information through the wider communications network. The account also describes the role of female auxiliary personnel who operated the projection and communications processes.

The Netherlands had documented Bertha installations at Terschelling, Zandvoort and Brielle; another was planned for Den Helder but was not built. That distribution illustrates how the L487 designation identifies a specialist radar-control role that could serve a wider area, rather than a single local gun battery. It should not be confused with an antenna bunker or the radar tower itself: the evaluation and fighter-direction function was the heart of the L487.

ServiceLuftwaffePrimary functionRadar evaluation and night-fighter direction (“Bertha”)Catalogue plan dataApprox. 22.9 × 22.1 m; 8.6 m high; 2,550 m³ concrete

Sources: Visit Wadden, “Communication and equipment”; Regelbau.dk, L487 model description; BunkerArchive type record.

11 / NAVAL RADAR · EQUIPMENT AND ANTENNA SUPPORT

Regelbau V174: The Radar Bunker with a Special Equipment Stand

Regelbau V174 is catalogued as a radar bunker or stand for radio-measuring and locating equipment with a special column. The German designation refers to an installation for Funkmeß- und Ortungsgerät and a Zerstörersäule. In practical terms, the structure formed a protected equipment base for a radar installation, combining internal protected spaces with a supporting structure for the radar equipment. Its architecture therefore differed from a crew shelter or a conventional gun casemate: the building had to accommodate technical equipment and interface with an exposed antenna or mounting structure.

The model data gives approximate dimensions of 16.1 metres by 12.9 metres, a height of 8 metres and a concrete volume near 850 cubic metres. The standard design is listed in the third quarter of 1943. The available technical record also notes substantial amounts of reinforcing steel and variation in radar tower heights according to terrain. The exact arrangement at a surviving site therefore depends on the equipment version and the surrounding topography.

Radar fit: why the model number is not enough

Sources are not completely consistent about the radar equipment fitted to every V174. Some model references associate the design with a Würzburg Riese system, while local Danish radar records identify a V174 installation at Agger with a FuMO 214 Würzburg Riese variant in May 1944. Other catalogues use a different designation. Those records should not be flattened into a single universal statement: the actual equipment fit needs to be established for the particular station from wartime records, surviving foundations or specialist site documentation.

V174 was one part of the coastal radar network. Its importance lay in providing a protected and stable platform for detection and reporting equipment. The antenna or radar tower might be visually dominant, but the bunker’s machinery, power, cabling and operational spaces were just as essential. A photograph of a tower base or rusted mounting is therefore useful evidence of a radar site, but it is not on its own enough to identify a particular transmitter or radar model.

Primary functionRadar equipment bunker / stand for radio-measuring and locating equipmentCatalogue plan dataApprox. 16.1 × 12.9 m; 8 m high; 850 m³ concreteEquipment caveatRadar designations differ between records; confirm the actual fit at each site

Sources: Regelbau.dk, V174 model record; Hanstholmregistreringen, marine radar installations; BunkerArchive type record.

What these eleven bunkers tell us about German fortification design

The selected Regelbau types show how a large coastal defence system depended on many small specialist tasks. The 621 and 622 protected infantry groups; the 634 gave a machine-gun crew an armoured turret; the 636 coordinated a coastal artillery battery; the 639 provided medical support; and the 666 and 668 added observation and local crew protection. The 671 housed a gun in a restricted-traverse casemate, while the L411A protected the machinery behind a searchlight. At the more complex end, L487 transformed radar plots into fighter-control decisions, and V174 provided a protected site for radar equipment.

These examples should not be collapsed into one universal “Atlantic Wall bunker”. Some were Army designs, some were Luftwaffe installations and some belonged to specialist naval or radar programmes. Some were built along the occupied coast; others in the wider German fortification system. Their common language was reinforced concrete and standardized planning, but their military functions were sharply different. That is what makes the Regelbau catalogue so revealing: it records not one fortress shape, but the many working parts of an engineered defensive network.

Sources and further reading

The research uses a combination of public heritage inventories, museum documentation, state heritage-management records, a regional history publication and specialist model catalogues. The catalogue database is useful for comparing standard plan entries, but it is community-maintained; measurements and model descriptions should therefore be checked against local inventories or original plans where possible.

Public heritage inventories and official records

Model catalogues and specialist reference pages

Image provenance and identification limits

The supplied JSON contains 5,582 records. Four duplicate image URLs were removed, leaving 5,578 unique image URLs across 91 exact type labels. Eight unique records were randomly selected for each of the eleven selected labels: 88 JSON-sourced images in total. Selection used the source file’s exact type value and original width/height metadata; all selected source-file images are 564 pixels wide. Each one links to the supplied pin ID on a randomly selected Pinterest regional domain. Additional photographs, where included, link to the external page from which their image was retrieved. The image JSON does not include original photographer credit, date, geographic coordinates or verification records, so captions identify the images as catalogue-tagged rather than claiming an independent archaeological identification. Exact duplicate URLs were excluded; near-duplicate visual comparison of every remote image could not be independently completed.

Back to top ↑

Comments

Popular posts from this blog

10 Regelbau Bunkers That Reveal the Atlantic Wall’s Hidden Secrets

10 Regelbau Bunkers That Reveal the Atlantic Wall's Hidden Design